Clifton mason, email, 27.Clifton Mason, 25. Aplicaciones De Ofimatica De Software Libre Y . I went through loadmaster school at Dover AFB June and July of 1964.I was stationed at Charleston.Ceiling Fan Installation In Tucson Az Temp' title='Ceiling Fan Installation In Tucson Az Temp' />Single Multi Flue Chimney Caps and Chimney Covers.Bill from MI asked August 1.Is it okay to overlap the pre existing mesh with more protective covering in my situationIm having a hard time with bats entering my house.Everything is sealed except my chimney cap has 34 mesh.It is a natural gas set up.Answers. We would not recommend overlapping the pre existing mesh as this could result in too little air space available for the exhaust fumes to escape from your chimney.If you have a pre fabricated chimney, we would suggest a louvered top replacement or changing to a cap with 58 mesh.Kelsey C. on August 1.Lance from Lewisville, TX asked July 2.I am not entirely sure how I need to measure for the chimney cap.I have a rough estimate of 4.Do I measure the inside or the entire chimney Answers.It would depend on how you would like the cap to mount.Images/1000/c5/c55c057c-b15e-409e-9d24-ad2d6e8b08de_1000.jpg' alt='Ceiling Fan Installation In Tucson Az Temp' title='Ceiling Fan Installation In Tucson Az Temp' />On a flue mounted cap, we would need the ID and OD of the flue itself.Pete from Pittsburgh, PA asked May 1.I have a wood burning fireplace and when temperature warms up outside or it rains, smell comes through wood burner.Do you make a chimney cap that spins and stops the air being pulled down Answers.There would not really be a cap design that would correct this issue with any assurance as the problems you are describing are the result of negative pressure.In the warmer months when customers turn on their homes HVAC for cooling, the fireplaces chimney will tend to draw in outside air as the return vent will pull floor level air up through the homes ventilation and push cool air out of the cooling registers near the ceiling.Since the pressure is not equalized, the force of a motorized blower fan will easily pull air down through the chimney, so I would recommend cracking a window to see if this is still happening once makeup air is being pulled from another location.If not, I recommend making sure the damper is in the fully closed position.If it is, consider installing doors to additionally restrict the amount of air that can be pulled through the fireplace opening.To address the downdraft when it rains outside, these two things could be related to the subsequent wind that comes along with rain and the chimney not being tall enough to prevent downdraft.In order to correct this, please ensure the chimney is at least 3 above the roof and then an additional 2 over any obstruction measured within 1.Diane from Dallas, TX asked April 3, 2.I have a chimney with outside dimensions of 6.Do you have anything to fit those dimensions Answers.While we will not have any stock caps that will mount on the outside of this chimney, most customers choose a product like our Multi Flue Semi Custom Gelco Chimney Cap 8 High Mesh to install on the chimney crown surface in between the outer perimeter of the chimney crown and flue tiles.We also have the ability to have caps custom fabricated with the dimensions you prefer.Bill from Long Island, NY asked March 2.I have an 8 X 8 and an 8 X 1.I need a custom cap that will fit over both and can still mount to the clay flue.The outside dimensions are 8.X 2. 412. Is this possibleAnswers.Yes it is possible, or you could use a crown mounted cap.Michele from Clyde, NC asked March 1, 2.I am looking for knock down or unassembled single flue caps.All Im seeing is multi flue.Do you have any suggestions Answers.The multi flue caps are shipped knock down.Brennan W. on March 1, 2.Jonathan from Newbury Park, CA asked February 1.I need a chimney cap and the opening is oval and 1.What size do you think I should get Answers.For a crown mounted cap, you should measure from the outside edge of the the flue, rounding up to nearest inch.Owen on February 1.Todd from Vacaville, CA asked January 3.I have a chimney that has an 8 x 2.I would like a chimney cap with cover.What can you recommend Answers.Please provide the measurement of the flat portion of your concrete crown surface before the steep slope towards the outer brick chimney.Also, we will need to know how many inches the flue tile extends from this surface to determine the proper mesh height.As you are in California, any cap recommendation will incorporate 58 mesh.Will M. on January 3.Charles from Bend, OR asked January 2.I have a Tr. 34. 4 chimney cap, presently, that I believe is more prone to creosote build up with the outside of the pipe spark arrest or vein construction.The inside pipe has very little build up, almost nothing.It is most prone during very cold days and nights.I have to wire brush it a couple of times a season.Answers. Creosote will form once the flue gases fall below 2.If this happens before the gases clear the pipe, or in you case the cap, it will condensate on the cooler surface.Mark from Marietta, GA asked December 1.I have a direct vent chimney cap on a Martin model BW4.A fireplace and would like to switch to a vented gas log fireplace.Do you have a cross reference for what cap I need to install Answers.You would simply need to convert this back to a functional wood burning fireplace.Any refractory panels that may have been removed for installation of the insert will need to be replaced and the direct vent cap and liner will need to be removed and replaced with a cap that is safe for use with a wood burning fireplace.As the listed caps for Martin Industries fireplaces have been discontinued for quite some time and I have no access to the flue dimensions, please provide the inside and outside diameter of your chimney so that we may locate a universal cap.Will M. on December 1.Joe Dorman from Seattle, WA asked December 9, 2.I would like to cap multiple flues that measure 2.The outside dimension of brick chimney is 4.Answers. We will be happy to make a recommendation.If you could, please let us know how far the flues extend off the top of the chimney.Brennan W. on December 9, 2.Doug from Richardson, TX asked December 5, 2.I need a 2. 4 X 3.Answers. The Multi Flue Semi Custom Gelco Chimney Cap 8 High Mesh has 34 reversible swing tabs at the base to allow for inside or outside mounting and 2.If this is not what you are needing, please provide further details so that we may look into other options.Will M. on December 6, 2.Barbara Jouett from Santa Barbara, CA asked December 2, 2.We are looking for an oval chimney cap for an older home.The unit is set onto an oval plaster shape over the basic chimney.After years, ours has was blown off in a strong wind.Answers. We will be happy to see if we have anything that would fit.What are the dimensions of the flueBrennan W.December 2, 2. Phil from New Mexico asked November 2.I need a high wind chimney cap for a pellet stove chimney.Beth Burkette from Denham Springs, LA asked November 2.Where would I find a chimney cap screen Doug from Dallas, TX asked November 2.I need a cheap 2.X 3. 6 cap preferably in black galvanized.Charlie from San Jose asked November 1.Id like to use a cap that goes around the brick.Dimensions 1. 5 12 x 2.Do you have a cap to fit that sizeMary from Sacramento, CA asked November 1.I own several residences at South Lake Tahoe, California, which have custom fireplaces all clean, but require chimney caps for new fire protection codes.How do I know which height 8, 1.Martin Luchak from Wiemar, Texas asked November 1.I have a 1. 00 year Catholic Church with a brick chimney.The outside dimension are 4.The boiler in the basement is exhausting into a 1.I would like it to be side mounted and material to be 2.Ron Brushaber from CT asked November 7, 2.Would you have a chimney cap that is 1.Chris from Mc. Minnville, TN asked November 5, 2.What size cap do I need for a CPF 2.ID pipe Charles from Tucson, AZ asked November 2, 2.What is the correct way to measure for a chimney capWe have a large fireplace floor to ceiling.Do I have to go onto the roof to measure the openingAlfred from Salem, NH asked October 2.I have a single flue chimney for a propane furnace where the flue does not go to the top.I am looking for a top mount cap with flanges on the outside for mounting to the top of the chimney.The size I need is 1.I do not know how high the screen should be for a propane furnace as far as air flow or draft.I plan to blot it and caulk it to the top of the chimney.Can you suggest the right cap for thisThank you.Answers. Based on your description, the Gelco Stainless Steel 1.Base Single Flue Chimney Cap would be a perfect match for your needs.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |